LBC-4000 L-Band Up/Down Converter System
MN/LBC4000.IOM
Specifications
Revision 5
2–3
2.1.7.5
Modular Design
(2) IDU Module bays (‘CONV A’ and ‘CONV B’) are located behind the drop-down
front panel.
2.1.7.5.1
LBC-4000 L-Band Up Converter IDU Module
Input Frequency
•
STANDARD:
70 MHz
±
18 MHz
•
OPTIONAL:
140 MHz
±
36 MHz
Output Frequency
950 MHz to 2000 MHz, 1 kHz steps
Input/Output Impedance
50
Ω
Input Return Loss
18 dB minimum
Output Return Loss
15 dB minimum
Input connector
BNC female
Output connector
Type ‘N’ female
Gain
25 dB
±
1 dB nominal at minimum attenuation
Ripple
•
±
.5 dB over any
±
18 MHz for standard 70 MHz IF units
•
±
.5 dB over any
±
36 MHz for optional 140 MHz IF units
Slope
0.05 dB/MHz
User Attenuation Range
0 to 40 dB, in 0.25 dB steps (STANDARD) or 0.1 dB steps
(OPTIONAL)
Input Power Level
To
±
10 dBm maximum
Output Power, P1dB
+10 dBm minimum
Third Order Intercept
+20 dBm minimum
Carrier Spurious
-60 dBc
Non-Carrier Spurious
-75 dBm
Transmit Phase Noise
Exceeds MIL-STD-188-164A
Stability
Over Time
±
1 X 10
-9
/Day
Over Temp
±
1 x 10
-8
32° to 122°F (0° to 50°C)
Содержание CD-MNLBC4000
Страница 72: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Firmware Update Revision 5 5 16 Notes...
Страница 154: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix A Revision 5 A 8 Notes...
Страница 164: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix B Revision 5 B 10 Notes...
Страница 165: ......
Страница 166: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...