LBC-4000 L-Band Up/Down Converter System
MN/LBC4000.IOM
Ethernet Interface Operation
Revision 5
7–23
7.5.3.5
Config | Serial
Use this page to configure LBC-4000 operating parameters over the EIA-485/232
serial interface.
Figure 7-15. Config | Serial page
Serial
Use the drop-down menu to select the operating serial mode as
RS-485
or
RS-232
.
Remote Address
Enter a valid remote control address from
0001
to
9999
.
Baud Rate
Use the drop-down menu to select the operating baud rate as
1200
,
2400
,
4800,
9600
,
19200
, or
38400
baud.
Data bits – Parity – Stop Bits
Use the drop-down menu to select the asynchronous character format as
8-N-1
(8 data bits, no parity, 1 stop bit);
7-O-2
(7 data bits, odd parity, 2 stop bits); or
7-E-2
(7 data bits, even parity, 2 stop bits).
Click
[Change Serial Configuration]
.