LBC-4000 L-Band Up/Down Converter System
MN/LBC4000.IOM
Front Panel Operation
Revision 5
6–16
Faults: Conv-A
▲
iflo=OK rflo=OK temp=OK
▼
Faults: Conv-B
▲
iflo=OK rflo=OK temp=OK
▼
These screens show the active Conv-A and Conv-B Up and/or Down Converter
IDU operating parameters fault states, where:
•
iflo
= IF Lockout Fault
•
rflo
= RF Lockout Fault
•
temp
= Operating Temp Fault (°C)
Faults: Power Supply A
▲
12VT=OK 08V=OK 05V=OK
▼
Faults: Power Supply B
▲
12VT=OK 08V=OK 05V=OK
▼
These screens show the active
PS A
and
PS B
(power supply) 12V, 8V, and 5V
fault states.
Faults: Ext Ref
▲
Ext Ref = FT
▼
This screen displays the external reference oscillator fault state.
Press
[ENT]
or
[CLR]
to continue.
6.2.5.2
(FAULTS:) STORED
VIEW CLEAR-ALL
Use the
[
][
]
arrow keys to select
VIEW
or
CLEAR-ALL
. Press
[ENT]
.