LBC-4000 L-Band Up/Down Converter System
MN/LBC4000.IOM
Front Panel Operation
Revision 5
6–8
change its value. Repeat for all digits until you define the desired
frequency.
Select the Tx/Rx mute status:
Use the
[
][
]
arrow keys on the bottom
line to select the parameter. Use the
[
][
]
arrow keys to select
ON
or
OFF
.
The displays reads ‘Tx’ when the installed module is an Up
Converter, or ‘Rx’ when the installed module is a Down
Converter.
Press
[ENT]
.
6.2.3.1.2
CONFIG CnvA or CnvB
ATTEN/SLOPE
For
CnvA
:
CONFIG CnvA: Ofst=+0.0dB
Atten=00.00dB Slope=0.0
For
CnvB
:
CONFIG CnvB:
Atten=00.00dB Slope=0.0
Typical for either, use the
[
][
]
arrow keys to select
Atten
or
Slope
.
Set the attenuation:
Use the
[
][
]
arrow keys to select a digit to edit,
and then use the
[
][
]
arrow keys to change its value.
Set the slope value:
Use the
[
][
]
arrow keys to select, in 0.1
increments, a value between 0.0 and 1.0.
For the
CONFIG: Conv-A
ATTEN/SLOPE
menu, the
Ofst
(Gain
Offset) command is available only if redundancy is enabled. See
Appendix B. REDUNDANCY OPERATION
for further details on
using this command in redundancy applications.
Press
[ENT]
.
Содержание CD-MNLBC4000
Страница 72: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Firmware Update Revision 5 5 16 Notes...
Страница 154: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix A Revision 5 A 8 Notes...
Страница 164: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix B Revision 5 B 10 Notes...
Страница 165: ......
Страница 166: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...