LBC-4000 L-Band Up/Down Converter System
MN/LBC4000.IOM
Front Panel Operation
Revision 5
6–17
6.2.5.2.1
(FAULTS:) STORED
VIEW
If you select
View
and no faults exist in the stored faults log, the system displays
this message:
No Stored Faults
.
Otherwise, stored faults log entries display as per this example:
Fault No. 06 10:28:53 ▲
OK-IFLO_A 08/10/16 ▼
Use the
[
][
]
arrow keys to page between screens. The faults log can store up
to
100
faults. When a fault condition occurs, the unit assigns a number to the
fault (in the order received), date- and time-stamps the fault, and provides a
condensed description of the issue. When the fault condition clears, this action is
recorded in the same fashion as the fault was originally recorded.
Once the number of faults reaches 100, the 100
th
fault displays as “
ER
.” The
stored faults remain in memory until you execute the
CLEAR-ALL
command.
Press
[ENT]
or
[CLR]
to return to the previous menu.
6.2.5.2.2
(FAULTS:) STORED
CLEAR-ALL
Clear All Stored Faults
No Yes
Use the
[
][
]
arrow keys to select
No
or
Yes
. Press
[ENT]
.
When you select
Yes
, the unit clears the faults log and returns you to the
previous menu. However, if there are faults present on the unit at this time, the
unit will re-stamp the faults and generate new log entries.
Содержание CD-MNLBC4000
Страница 72: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Firmware Update Revision 5 5 16 Notes...
Страница 154: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix A Revision 5 A 8 Notes...
Страница 164: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix B Revision 5 B 10 Notes...
Страница 165: ......
Страница 166: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...