8.3.5
CAS (Concise Alarm Status)
Query only. Use “CAS” to return the Alarm Status for the unit.
Controller-to-Target
Instruction Code and Qualifier
Arguments for
Command or
Response to
Query
Description of Arguments
Target-to-Controller
Response
Command
Query
Command
Query
N/A
CAS_
13 bytes,
numeric
Returns alarm status as 0 = NO FAULT or 1 =
FAULT for each item in the form
“CAS_abcdefghijklm{cr}{lf}” where:
a=12VDC #1 Fault
b=8VDC #1 Fault
c=5VDC #1 Fault
d=12VDC #2 Fault
e=8VDC #2 Fault
f=5VDC #2 Fault
g=REF LD Fault
h=IFLO A Fault
i=RFLO A Fault
j=TEMP A Fault
k=IFLO B Fault
l=RFLO B Fault
m=TEMP B Fault
N/A
CAS_x…x
8.3.6
CCS (Concise Configuration Status)
Query only. Use “CCS” to return a summarized version of the RCS query.
Controller-to-Target
Instruction Code and Qualifier
Arguments for
Command or
Response to
Query
Description of Arguments
Target-to-Controller
Response
Command
Query
Command
Query
N/A
CCS_
52 bytes,
numeric
Returns status info in the form
“CCS_aaaaa.aaabb.bbcd.defffff.fffgg.gghi.ijklmnnno
pqqqqrs{cr}{lf}” where:
aaaaa.aaa=Conv A frequency in MHz
bb.bb=Conv A attenuation in dB
c=Conv A mute state (0=unmuted, 1=muted)
d.d=Conv A slope adjustment level
e=Conv A online/offline (redundancy)
fffff.fff=Conv B frequency in MHz
gg.gg=Conv B attenuation in dB
h=Conv B mute state (0=unmuted, 1=muted)
i.i=Conv B slope adjustment level
j=Conv B online/offline (redundancy)
k=Converter redundancy mode
l=auto fault recovery (1=auto, 0=manual)
m=External Ref present (0=none, 1=present)
nnn=Internal Ref Osc adjustment level (000-255)
o=remote mode (1=remote, 0=local)
p=remote interface (0=EIA-232, 1=EIA-485)
qqqq=remote address (0001-9999)
r=remote baud rate (0=38400, 1=19200, 2=9600,
3=4800, 4=2400, 5=1200)
s=remote data format (0=8N1, 1=7E2, 2=7O2)
N/A
CCS_a…s
Содержание CD-MNLBC4000
Страница 72: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Firmware Update Revision 5 5 16 Notes...
Страница 154: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix A Revision 5 A 8 Notes...
Страница 164: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix B Revision 5 B 10 Notes...
Страница 165: ......
Страница 166: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...