LBC-4000 L-Band Up/Down Converter System
MN/LBC4000.IOM
Front Panel Operation
Revision 5
6–9
6.2.3.2
(CONFIG:) REMOTE (Remote Control) Submenu
Remote Control: Local
SERIAL ETHERNET
Use the
[
][
]
arrow keys to select
Local
,
SERIAL
, or
ETHERNET
. Press
[ENT]
.
6.2.3.2.1
(REMOTE:) Local
1)
When you select Local mode, remote monitoring is possible, but
remote control is
disabled
.
2)
A number of operations are possible in Local mode only. If you are
in Serial or Ethernet mode during such tasks, the unit alerts you to
this remote state:
Remote Mode: press ENT
for local mode, or CLR
Press
[ENT]
to switch to Local Mode to continue with your task, or
press
[CLR]
to exit the task and remain in the active mode.
6.2.3.2.2
(REMOTE:) SERIAL
Serial Mode = RS-232
Addr=001 Baud=9600 8-N-1
On the top line, use the
[
][
]
arrow keys to set the mode to
RS-232
or
RS-485
.
On the bottom line, set the Serial address (
Addr
). Use the
[
][
]
arrow keys to
select a digit, and then the
[
][
]
arrow keys to change its value. The valid
range of addresses is from
001
(default) to
255
.
Next, set the
Baud
rate. Use the
[
][
]
arrow keys to select the parameter, and
then the
[
][
]
arrow keys to select the desired baud rate of
1200
,
2400
,
4800
,
9600
(default),
19K2
, and
38K4
.
Содержание CD-MNLBC4000
Страница 72: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Firmware Update Revision 5 5 16 Notes...
Страница 154: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix A Revision 5 A 8 Notes...
Страница 164: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix B Revision 5 B 10 Notes...
Страница 165: ......
Страница 166: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...