LBC-4000 L-Band Up/Down Converter System
MN/LBC4000.IOM
Appendix B
Revision 5
B–9
B.4.3
SAM (Set Auto/Manual Switching Mode)
Command or Query. Use “SAM” to set or return the operating redundancy
switching mode as Automatic or Manual.
Controller-to-Target
Instruction Code and Qualifier
Arguments for
Command or
Response to
Query
Description of Arguments
Target-to-Controller
Response
Command
Query
Command
Query
SAM_
SAM_
1 byte,
alphabetic
Set or return in the form SAM_x where:
x=A (Automatic Switching Mode) or M (Manual
Switching Mode)
SAM_
SAM_x
Command Example:
<0001/SAM_M{cr}