LBC-4000 L-Band Up/Down Converter System
MN/LBC4000.IOM
Serial Interface Operation
Revision 5
8–11
8.3.7
CMM (Configure Mute Mode)
Command or Query. Use “CMM” to set or return the mute mode.
Controller-to-Target
Instruction Code and Qualifier
Arguments for
Command or
Response to
Query
Description of Arguments
Target-to-Controller
Response
Command
Query
Command
Query
CMM_y_xxx
CMM_y_
5 bytes,
alphabetic
Set or return in the form CMM_y_xxx where:
y=A (Conv A) or B (Conv B)
xxx=ON (mute) or OFF (unmute)
CMM_y_xxx
CMM_y_xxx
Command Example:
<0001/CMM_A_OFF{cr} (Unmutes Converter A)
8.3.8
CMS (Concise Maintenance Status)
Query only. Use “CMS” to return a summarized version of the maintenance
status.
Controller-to-Target
Instruction Code and Qualifier
Arguments for
Command or
Response to
Query
Description of Arguments
Target-to-Controller
Response
Command
Query
Command
Query
N/A
CMS_
85 bytes,
numeric
Returns status info in the form
“CMS_aaa.abbb.bccc.cddd.deee.efff.fggg.ghhh.hiii
.ijjj.jkkk.klll.lmmm.mnnn.nooo.oppp.pqqq.q{cr}{lf}”
where:
aaa.a=12 VDC supply #1 in volts
bbb.b=8 VDC supply #1 in volts
ccc.c=5 VDC supply #1 in volts
ddd.d=12 VDC supply #2 in volts
eee.e=8 VDC supply #2 in volts
fff.f= 5 VDC supply #2 in volts
ggg.g=Ref Osc tuning in volts
hhh.h=Converter A IFLO tuning in volts
iii.i= Converter A RFLO tuning in volts
jjj.j=Converter A Input Power in dBm (Reserved for
future use)
kkk.k=Converter A Output Power in dBm
(Reserved for future use)
lll.l= Converter A temperature in degrees C
mmm.m=Converter B IFLO tuning voltage in volts
nnn.n= Converter B RFLO tuning voltage in volts
ooo.o=Converter B Input Power in dBm (Reserved
for future use)
ppp.p=Converter B Output Power in dBm
(Reserved for future use)
qqq.q=Converter B temperature in degrees C
N/A
CMS_a…q
Содержание CD-MNLBC4000
Страница 72: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Firmware Update Revision 5 5 16 Notes...
Страница 154: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix A Revision 5 A 8 Notes...
Страница 164: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix B Revision 5 B 10 Notes...
Страница 165: ......
Страница 166: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...