LBC-4000 L-Band Up/Down Converter System
MN/LBC4000.IOM
Serial Interface Operation
Revision 5
8–13
8.3.12
FRE (Operating Frequency)
Command or Query. Use “FRE” to set or return the operating frequency, in MHz.
Controller-to-Target
Instruction Code and Qualifier
Arguments for
Command or
Response to
Query
Description of Arguments
Target-to-Controller
Response
Command
Query
Command
Query
FRE_
FRE_y_
11 bytes,
alphanumeric
Set or return info in the form FRE_y_ xxxxx.xxx
where:
y=A (Conv A) or B (Conv B)
xxxxx.xxx=valid operating frequency, in MHz, entered
in 1kHz steps.
FRE_
FRE_y_
xxxxx.xxx
Note:
You have the option to set the frequency, for example, to Ku-Band 14500.000
MHz, if the ‘frequency display select’ option is turned ON.
Command Example:
<0001/FRE_A_00951.000{cr}
8.3.13
FRL (Fault Relay Logic)
Command or Query. Use “FRL” to set or return the fault relay logic.
Controller-to-Target
Instruction Code and Qualifier
Arguments for
Command or
Response to
Query
Description of Arguments
Target-to-Controller
Response
Command
Query
Command
Query
FRL_
FRL_
1 byte, numeric Set or return info in the form FRL_x where:
x=0 (Normal Logic) or 1 (Inverted Logic)
FRL_
FRL_x
Содержание CD-MNLBC4000
Страница 72: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Firmware Update Revision 5 5 16 Notes...
Страница 154: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix A Revision 5 A 8 Notes...
Страница 164: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix B Revision 5 B 10 Notes...
Страница 165: ......
Страница 166: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...