LBC-4000 L-Band Up/Down Converter System
MN/LBC4000.IOM
Serial Interface Operation
Revision 5
8–5
defines the
command
configuration parameters that are issued to the
Target.
For example, the Controller-to-Target command “<0001/MUT_A_ON{cr}”
means ‘turn ON the mute function of Converter A’.
2.
The ‘_’ underscore, when submitted Controller-to-Target without
parameters, functions as a
query
. Submitted in this format, the Controller
directs the Target to report the current configured value for that
parameter (Instruction Code).
For example, the Controller-to-Target query “<0001/MUT_A_{cr}” means
‘return the current state of the mute function of Converter A’.
3.
From
Target-to-Controller
, if the instruction sent from Controller-to-
Target is successful, the Target responds by echoing that same instruction
to the Controller.
8.2.1.5.1
Error Response
If a Target cannot execute a Command or detects a protocol violation, the
Controller generates an error response. For example:
>0001?RED ER Error Message{cr}{lf}
Note that:
•
The "/" address delimiter changes in the response to a "?".
•
The Instruction Code is echoed, followed by two unique characters
provided for analysis. This example uses “ER”.
•
A text string explaining the error follows.
8.2.1.6
Optional Message Arguments
Arguments are not required for all messages. Arguments include these ASCII
codes:
•
Characters ‘0’ through ‘9’ (ASCII codes 48 through 57)
•
Period ‘.’ (ASCII code 46)
•
Comma ‘,’ (ASCII code 44)
Содержание CD-MNLBC4000
Страница 72: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Firmware Update Revision 5 5 16 Notes...
Страница 154: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix A Revision 5 A 8 Notes...
Страница 164: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix B Revision 5 B 10 Notes...
Страница 165: ......
Страница 166: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...