LBC-4000 L-Band Up/Down Converter System
MN/LBC4000.IOM
Serial Interface Operation
Revision 5
8–20
8.3.30
RET_y_ (Retrieve Module Type)
Query only. Use “RET” with an argument to return the operating frequency and
function (i.e., up/down) of the selected module.
Controller-to-Target
Instruction Code and Qualifier
Arguments for
Command or
Response to
Query
Description of Arguments
Target-to-Controller
Response
Command
Query
Command
Query
N/A
RET_y_
12 bytes,
alphanumeric
Query, when used with argument y, where:
y=A (Conv A) or B (Conv B)
returns a string in the form RET_y_xxx_ZZ where:
xxx=Frequency of selected module (070 or 140)
ZZ=UL (Uplink) or DL (Downlink)
N/A
RET_y_x...Z
Query Examples:
<0001/RET_A_{cr}
>0001/RET_A_140_DL{cr}{lf}
<0001/RET_B_{CR}
>0001/RET_B_070_UL{cr}{lf}
8.3.31
RMS (Retrieve Maintenance Status)
Query only. Use “RMS” to return the maintenance status of the unit.
Controller-to-Target
Instruction Code and Qualifier
Arguments for
Command or
Response to
Query
Description of Arguments
Target-to-Controller
Response
Command
Query
Command
Query
N/A
RMS_
203 bytes,
alphanumeric
Returns detailed maintenance status for the unit:
N/A
RMS_x...x
12VT1=xxx.x{cr}
08VT1=xxx.x{cr}
05VT1=xxx.x{cr}
12VT2=xxx.x{cr}
08VT2=xxx.x{cr}
05VT2=xxx.x{cr}
VTREF=xxx.x{cr}
IFLOA=xxx.x{cr}
RFLOA=xxx.x{cr}
PIN_A=xxx.x{cr}.
POUTA=xxx.x{cr}
TEMPA=xxx.x{cr}
IFLOB=xxx.x{cr}
RFLOB=xxx.x{cr}
PIN_B=xxx.x{cr}
POUTB=xxx.x{cr}
TEMPB=xxx.x{cr}
12VDC Supply #1 in volts
8VDC Supply #1 in volts
5VDC Supply #1 in volts
12VDC Supply #2 in volts
8VDC Supply #2 in volts
5VDC Supply #2 in volts
Ref Osc tuning in volts
Conv A IFLO tuning in volts
Conv A RFLO tuning in volts
Conv A Input power in dBm
Conv A Output power in dBm
Conv A temperature in deg C
Conv B IFLO turning in volts
Conv B RFLO tuning in volts
Conv B Input power in dBm
Conv B Output power in dBm
Conv B temperature in deg C
Содержание CD-MNLBC4000
Страница 72: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Firmware Update Revision 5 5 16 Notes...
Страница 154: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix A Revision 5 A 8 Notes...
Страница 164: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix B Revision 5 B 10 Notes...
Страница 165: ......
Страница 166: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...