LBC-4000 L-Band Up/Down Converter System
MN/LBC4000.IOM
Ethernet Interface Operation
Revision 5
7–18
Converter A / Converter B
Frequency in MHz
– Enter an operating RF Frequency (if the converter is a Ku-
Band down converter) in the range of
10950
to
12750
MHz; otherwise, this field
displays as
N/A
.
Attenuation (dB)
– Enter a valid attenuation level (
00
.
00
to
20
.
00
dB) in 0.25 dB
steps.
Attenuation Offset (Conv A page only):
Enter a valid value, in dB, for the
attenuation offset.
Click
[Change Configuration]
. Click
[Reset]
to revert to the previously assigned
parameters (
Conv B page only
).
Mute
Use the drop-down list to set the Configuration Mute Mode as
On
or
Off
. Click
[Change]
.
Carrier Mute Mode
Use the drop-down list to set the Carrier Mute Mode as
On
or
Off
. Click
[Change]
.
Slope
Enter a slope value (
0.0
to
1.0
) in 0.1 steps. Click
[Change]
when done.
Spectrum Inversion
Use the drop-down menu to select the Spectrum Inversion function as
INV
or
NRM
(Normal), and then click
[Change]
.