background image

San Telequip Private Limited., 
504 & 505 Deron Heights, Baner Road 
Pune 411045, India 
Phone   : +91-20-27273455, 9764027070, 8390069393                   Connecting. Converting. Leading! 
email     

[email protected]

  

 

 

 

 

                           

                        

Document Name: User Manual for Self-Healing Serial to Fiber Converter Model SC12 FS SHI 

The SC12FS SHI is used to transmit the RS232 / RS485 / RS422 signal by the fiber optic ring network at a high rate, 
over long distances, offering immunity to various types of noise and increasing the dependability of data. 

The communications system model of SC12FS SHI is one Master to multiple Slaves. 
It is easy to structure a network of Star, Chain and Loop type. 

It is a Self-Healing product. When any of Slave nodes fails or the Power is cut off or there is a break in fiber etc, 
the communication shifts to the alternate loop & resumes normal communication, through the normal loop, once 
the fault is restored. 

For forming a Ring, you need at least 3 converters else it is a Point to Point communication 

  

Specifications : 

  

  

  

  

  

  

  

  

Ports 

  

  

  

  

  

  

  

  

Fiber * 2 

  

: Full Duplex 

  

  

  

  

Code error rate 

  

: below 10-9 

  

  

  

  

Wavelength 

  

: SM 

:1310 / 1550 nm, MM 

:1310 / 850 nm 

  

Cable 

  

: SM 

: 09/125 

  

  

  

  

  

  

: MM : 62.5/125 

m or 50/125 

  

  

  

Fiber Connectors 

  

: ST, SC or FC. Select any one. 

  

  

  

  

Distance 

  

: SM: 20km, MM: 2 to 5km. Longer distances are available as options in SM 

  

Tx Power 

  

: -8.5dbm 

  

  

  

  

Sensitivity 

  

: -35 dbm 

  

  

  

  

Code 

  

: HDB3 

  

  

  

  

  

  

Serial * 1 

  

: RS232/RS485/RS422 

  

  

  

  

Serial Port Connector 

: 7 pin screw type connectors 

  

  

  

  

Baud Rate 

  

: 300bps to 115.2Kbps 

  

  

  

  

Power 

  

  

  

  

  

  

  

  

Power supply 

  

: Options: DC 12 ( 9-18V), 24 ( 18 to 36V), 48 ( 36 to 72V), 110-370V 

  

  

  

  AC 110 to 270V 

  

  

  

  

  

  

: Dual Redundancy for DC 12, 24 & 48V DC Inputs 

  

  

Power 

  

: <2W 

  

  

  

  

  

  

Relay 

  

: Alarm Relay: 24V DC 1 Amp 

  

  

  

  

 
Mechanicals 
 

  

  

  

  

  

  

  

  

Dimensions                 : 144mm × 97mm ×33mm 

  

  

  

  

Weight                         : 500 gm 

  

  

  

  

  

  

Mounting                      : DIN Rail 

  

  

  

  

Operating Conditions 

  

  

  

  

  

  

  

Working temperature   : -20 to +75 °C. 

  

Storage temperature    : -40 to +85 °C. 
Relative humidity          : 95% non-condensation 

  

  

  

  

  

  

  

  

  

  

Protection 

  

  

  

  

  

  

  

  

MTBF                            : Better than 100,000 hours 

  

  

  

  

ESD Protection             : 15 KV ESD Surge Protection for all signals (Optional) 

  

Isolation Protection       : 2.5KV Optical Isolation for Power and Signals (Optional) 

  

Surge Protection           : 600W on RS485 lines 

  

 

 

 

 

 

 

 

Отзывы: