2291e-en_TroubleShooting_bedingt.fm, 25.08.2017
P1890E/EN 2013-08
45
Troubleshooting
10
Problem
Possible cause
Measure for mPro400GC
(SW S168813)
Measure for mPro400S…
(example SW 168841)
1)
RF15.4 data communication between controller and tool
No serial communica-
tion between the con-
troller and the base
station.
(error message is dis-
played after
Accept
<F1> softkey
is pressed under
Communication/
Tool
.)
Wrong serial cable is
being used.
Use zero modem cable (crossed).
Incorrect interface
selected for the con-
nection to the control-
ler.
On the control screen
Tool
Setup > Wireless Settings
.
Check
RF Mode
.
On the control screen
Main
Menu > System Programming
> Service > TMA Configura-
tion > Communication with
Tool
, check the
RF Mode
.
Check whether the serial connecting cable is connected to the
selected interface.
Selected interface is
used for serial data
transmission.
Do not use the same interface for serial data transmission and infrared
data transmission.
On the control screen
Communi-
cation > Data Transmission
Is serial data transmission
activated (selection
RF Mode
is not
None
)
Is the same interface
selected.
If so, select a different inter-
face or deactivate serial data
transmission.
All tools must be checked.
Check on the control screen
Main
menu > System Programming >
Service > TMA Configuration >
Communication with Tool
Is serial data transmission
activated (selection
RF Mode
is not
None
)?
Is the same interface
selected?
If yes, select another inter-
face under
Main Menu > Sys-
tem Programming < System
Programming > Serial Ports
Disable serial data transmis-
sion.
All tools must be checked.
Supply voltage not
active.
Check the socket to which the power supply unit for the base sta-
tion is connected.
No data communica-
tion between the con-
troller and tool.
Settings were not
entered correctly.
On the control screen
Com-
munication>Tool
check
whether the RF settings for
the base station match the
tool settings.
On the control screen
Main
Menu > System Programming
> Service > TMA Configura-
tion > Communication with
Tool
>
RF Mode
868 MHz
,
check whether the RF set-
tings for the base station
agree with the settings for the
tool.
Parameterize the tool with the
correct settings via the infra-
red interface.
The tool settings are displayed on the tool in the
Wireless Settings
submenu and can be modified if required.
The settings for
Channel
,
Network ID
and
Tool ID
must agree.
Distance between the
base station and tool
is too great.
Distance should not exceed 30 m.
Decrease the distance between the base station and the tool and
check whether communication is possible.
If so, increase the power on the base station and
tool or
reduce the distance between the base station and the tool.
Содержание 17BP
Страница 1: ...17BP Cordless EC tool Instruction Manual P1890E EN 2017 06...
Страница 20: ...Initial operation 7 20 P1890E EN 2017 06 2291b en_1_3_bedingt fm 25 08 2017...
Страница 38: ...38 P1890E EN 2017 06 2291c enu_LCD_bedingt fm 25 08 2017 LCD display 8...
Страница 48: ...48 P1890E EN 2013 08 2291e en_TroubleShooting_bedingt fm 25 08 2017 Troubleshooting 10...
Страница 55: ...1890g en_TechnDaten fm 25 08 2017 P1890E EN 2017 06 55 Technical specifications 12...