2291e-en_TroubleShooting_bedingt.fm, 25.08.2017
P1890E/EN 2013-08
41
Troubleshooting
10
10
Troubleshooting
Problem
Possible cause
Measure for mPro400GC
(SW S816813)
Measure for mPro400S…
(example SW 816841)
1)
1) Software-dependent measure. Discrepancy possible when using Custom Tool Software.
General tool
Tool doesn't start with
counterclockwise
rotation activated.
With counterclock-
wise rotation, param-
eter for speed is set
to
0 1/min.
Parameterize
Speed left rotation
On the control screen
Standard >
Standard Application Builder >
Tool Groups
On the control screen
Main Menu
> Application Builder > Tool
Groups
Tool light disabled.
Disabled by parame-
ter setting.
Parameterize the
tool light
On the control screen
Advanced
> Tool Settings > LiveWire Set-
tings
Press <
> on the control.
Select the required tool under
TM Unit #
>
Tool Assign-
ment
.
Press <
>.
Make selection under
Nutrun-
ner
Lighting Function
.
Control menu on tool
not enabled or only
partially enabled.
Disabled by parame-
ter setting.
On the control screen
Advan-
ced > Tool Settings >
LiveWire Settings
, mark the
check box
Enable Tool
Menu
or use the drop down
list
F1 Button on Tool
to
assign the left function key
<F1>.
Press <
> on the control.
Select the required tool under
TM Unit #
>
Tool Assign-
ment
.
Press <
>.
Select function under
Cont-
rol Button Settings
.
Default = Control menu
disabled.
Idle speed not
reached.
Battery voltage is too
low.
Use fully charged battery.
Expected number of
test rundowns is not
achieved with one
charge of the battery.
Battery is not fully
charged.
Use fully charged battery.
The warning thresh-
old for undervoltage
is not set to minimum
value.
On the control screen
Tool
Setup > Tool Settings
, reduce
the
Undervoltage (V)
.
Press <
> on the control.
Select the required tool
TM
Unit #
> under
Tool Assig-
nment
Press <
>.
Under
Energy Management
reduce the
Undervoltage
Threshold
.
High torque is
needed during a fas-
tening sequence, e.g.
for coated fasteners.
If a high torque is needed for a longer period of time, e.g. for several
turns, the number of rundowns that can be achieved with one battery
charge will be significantly reduced.
Battery has too many
charging cycles.
After 800 charging cycles the capacity is reduced to approx. 60%.
Содержание 17BP
Страница 1: ...17BP Cordless EC tool Instruction Manual P1890E EN 2017 06...
Страница 20: ...Initial operation 7 20 P1890E EN 2017 06 2291b en_1_3_bedingt fm 25 08 2017...
Страница 38: ...38 P1890E EN 2017 06 2291c enu_LCD_bedingt fm 25 08 2017 LCD display 8...
Страница 48: ...48 P1890E EN 2013 08 2291e en_TroubleShooting_bedingt fm 25 08 2017 Troubleshooting 10...
Страница 55: ...1890g en_TechnDaten fm 25 08 2017 P1890E EN 2017 06 55 Technical specifications 12...