2291c-enu_LCD_bedingt.fm, 25.08.2017
P1890E/EN 2017-06
35
LCD display
8
8.3.9
LMC submenu
8.4
System error messages
MAC address display.
Display LMC serial number.
Display whether LiveWire API (Application Programming Interface) is active.
If an error is displayed, fastening is disabled until the error is acknowledged with the left-hand button on the
tool. In the event of serious hardware errors, the tool is not enabled again even after the error is
acknowledged, and must be returned to the manufacturer for repair.
Initialization error in tool servo.
Remove the battery and then re-insert it. If this does not help:
Return tool to
Sales & Service Centers
for repair.
Speed specification from the measuring board to the servo is faulty.
Remove the battery and then re-insert it. If this does not help:
Return tool to
Sales & Service Centers
for repair.
Too much power is being demanded from the tool.
Switch the tool off for a time so that it can cool down.
Increase the cycle time, reduce the fastening time or the torque.
The servo's current sensor is detecting a current offset error.
Return tool to
Sales & Service Centers
for repair.
Collective servo error caused by hardware.
Return tool to
Sales & Service Centers
for repair.
MAC
00302e
e162f8
S: 5800
00008D
54C823
LW API
Active
No
Servo
Error
Init
Servo
Error
PWM
Servo
Error
IIT
Servo
Error
IOFF
Servo
Error
Other
Содержание 17BP
Страница 1: ...17BP Cordless EC tool Instruction Manual P1890E EN 2017 06...
Страница 20: ...Initial operation 7 20 P1890E EN 2017 06 2291b en_1_3_bedingt fm 25 08 2017...
Страница 38: ...38 P1890E EN 2017 06 2291c enu_LCD_bedingt fm 25 08 2017 LCD display 8...
Страница 48: ...48 P1890E EN 2013 08 2291e en_TroubleShooting_bedingt fm 25 08 2017 Troubleshooting 10...
Страница 55: ...1890g en_TechnDaten fm 25 08 2017 P1890E EN 2017 06 55 Technical specifications 12...