3-Point Bend Test Setup
1. Set the test mode to compression (
Settings
>
Test Mode
>
Compression
)
2. Install the desired load cell for vertical configuration (see
Appendix B
)
3. Attach a locking disc to the measuring end of the load cell.
4. Assemble the 3-Point Bending Block and sliders:
•
Attach M2x6 fasteners on the sides of the sliders and bending blocks
•
Place 4-40 -
5/16” fasteners through the hole and the square nuts. Place the
square nuts through the groove of the bottom block.
•
Use the large O-Rings and small O-Rings as illustrated below to hold the 3-point
bending dowels in place (Note: Choose a dowel size appropriate for the test
being performed. Small and Large dowels are provided with the 3-Point Bend
package).