9.
CAUTION:
Be sure to use the network cable with Category 5e or
higher. In addition, a shielded type (STP cable) is
recommended. When using the non-shielded type
(UTP cable), it may influence the surrounding
electronic equipments via network cable.
Use the correct power cord to match the location/area
of installation. Make sure not to leave unused power
cord at the site.
2x
Straight Ethernet Cable
(for network connection)
10.
Connect the power plug to the outlet of the host
machine.
11.
Connect the power plug to the outlet of the
equipment.
CAUTION:
Be sure to use an outlet of a system different from that
of the host machine.
12.
After turning ON the power of this equipment, turn
ON the main power switch of host machine.
13.
When the message "Turn ON the main power of the
host machine again." is displayed on the Touch
Panel, turn OFF the main power switch. (It may take
approx. 10 minutes before the message appears.)
CAUTION:
The equipment is automatically restarted only at the
first time when it is connected.
It takes about approx. 5 minutes until it is ready for use.
Do not press the buttons on the equipment until it is
ready for use.
14.
Turn ON the main power switch of the host machine
again.
15.
Check that the value of the following service mode
is "467".
COPIER > OPTION > INT-FACE > CNT-TYPE
16.
Exit from Service Mode.
6. INSTALLATION PROCEDURE
84
Содержание imagePASS-P2
Страница 1: ...Revision 1 1 imagePASS P2 Service Manual ...
Страница 6: ...Introduction 1 Introduction 2 Specifications 6 ...
Страница 13: ...Using the imagePASS 2 Using the imagePASS 9 ...
Страница 16: ...Figure 3b The imagePASS Tools menu 2 Using the imagePASS 11 ...
Страница 17: ...REPLACING PARTS 3 Replacing Parts 13 ...
Страница 44: ...INSTALLING SYSTEM SOFTWARE 4 Installing System Software 40 ...
Страница 64: ...TROUBLESHOOTI NG 5 Troubleshooting 60 ...
Страница 84: ...2 Stepped Screw M4 2x 3 4x Screw with Toothed Washer M4x8 Stepped Screw M4 4 4x 8x 6 INSTALLATION PROCEDURE 79 ...
Страница 87: ...2 2x Stepped Screw M4 3 Screw with Toothed Washer M4x8 Stepped Screw M4 6x 4 4x 8x 6 INSTALLATION PROCEDURE 82 ...
Страница 88: ...5 4x Screw with Toothed Washer M4x8 6 Crossover Ethernet Cable 1x 2x 7 2x 8 2x 6 INSTALLATION PROCEDURE 83 ...