Chapter 5 Web-Based Operations
204
Lynx DSA User's Manual - 9240227J
The Lynx unit may be positioned to either side. Verify any clearance or rear-access
concerns in your equipment rack when considering placement for a single unit.
•
Position one SHCS to the upper screw hole and one SHCS to the lower screw
hole from inside the half-filler piece, and into the Lynx main unit. Tighten
the screws until snug with your Allen wrench; do not over-tighten the screws.
•
You will use two provided flat-head Phillips screws, provided in the kit, to
attach each of the rack bracket/handles to the side of the joined units.
Position the handles to the forward-most holes on the side of the Lynx unit.
After the components are assembled, it should be sturdy and without flexing or
movement.
•
Remove and discard the rubber feet from the bottom of the Lynx unit.
•
Install the joined components in any 2U (3.5 inch) opening into the front of
your equipment rack, using your Rack's mounting screws.
Finally, connect the power, network, antenna and Acquisition device cables as usual.
Rack-mounting Two Units
Remove the contents of the Rack Mount kit from its packing material.
You will join two Lynx units side-by-side. Of two units, the one positioned to the
right as you are facing them must have its cover removed to join the units.
Note: You will also need an Allen Wrench (4 mm or 5/32") and a #2 Phillips
screwdriver. You will also use mounting hardware from your rack system to
mount the joined components into your rack. You will
not
use the filler piece.
CAUTION
:
You must remove the top cover of only
one
of the Lynx
units. In doing so, take care to prevent electro-static
discharge, and while handling the equipment, you
should minimize your contact with or near its internal
components.