220
LCD Message
Description
Corrective Action
UPS E10
Dependent Mode
The TeraStation is running on the UPS
battery due to a power outage. The
system will now be shut down safely.
Check that power is being supplied to the
UPS, and if there are no problems, turn on
the TeraStation.
SYSTEM Error E11
Fan Failure
An error occurred in the fan speed.
Check that no foreign objects or dust are
clogging the fan. If any foreign objects or
dust are found, use a pair of tweezers, air
duster, or other tool to remove them. If the
error is displayed again, contact Buffalo
technical support for assistance.
SYSTEM Error E12
Cooling Failure
A rise in the system temperature may
have exceeded the allowable safety value.
Do not place objects in the area around the
TeraStation. Also, move the TeraStation to a
cool location.
RAID Arrayx E14
Can't Mount
RAID array x cannot be mounted.
Run the RAID array disk check in Settings.
HDx Error E16
HDx Not Found
Unable to find hard drive x.
Hard drive x may be disconnected or may
have failed. After shutting down, reinstall
the hard drive.
HDx Error E22
HDx Can't Mount
Unable to mount drive x.
Format the hard drive. After formatting,
if the error still appears after rebooting,
replace the hard drive. If the error is
displayed again, contact Buffalo technical
support for assistance.
FailOver E27
LostBackupTarget
Unable to find the backup TeraStation.
In the main TeraStation's settings, navigate
to
Backup
-
Failover
to reconfigure the
backup TeraStation for failover.
HDx Broken E30
Replace the DISK
An error occurred, so hard drive x was
removed from the RAID array.
Replace hard drive x.
Status
After you change settings or format a hard drive, the current status is displayed on the LCD.
LCD Message
Description
Corrective Action
SYSTEM I10
TOO HOT !
System temperature is too high.
Move the TeraStation to a cool location. Do
not place objects in the area around the
TeraStation.
HDx Warning I11
Bad Sectors
Drive x has too many bad sectors.
Replace hard drive x.
Operation I12
DEGRADE MODE
Operating in degraded mode.
-
RAID I13
ARRAYxFormatting
Formatting RAID array x.
-
RAID I14
ARRAYx Checking
Checking RAID array x.
-
RAID I15
ARRAYx Scanning
Examining the error status of RAID array
x.
Note:
Transfer speeds are slower during
the examination process.
-
RAID I16
ARRAYx Creating
Creating RAID array x.
-
RAID I17
ARRAYx Resyncing
Resynchronizing RAID array x.
Note:
Transfer speeds are slower during
resynchronization.
-
Содержание TeraStation WSS 5000
Страница 10: ...9 Chapter 1 Installation Diagrams TS5800D TS5800DN TS5800DWR µ µ µ µ TS5600D TS5600DN µ µ µ µ ...
Страница 60: ...59 6 Click Edit under NAS Volume 7 Click Create Volume ...
Страница 67: ...66 2 Select the TeraStation name from the drop down menu of Target and click Register iSCSI Device 3 Click OK ...
Страница 88: ...87 2 Click to the right of Backup 3 Click List of LinkStations and TeraStations ...
Страница 90: ...89 3 Click Create New Job Note Up to 8 backup jobs can be configured ...
Страница 104: ...103 18Click Time Machine ...
Страница 105: ...104 19Click Select Backup Disk 20Select the TeraStation then click Use Disk ...
Страница 116: ...115 3 Click Create New Job ...
Страница 117: ...116 4 Select backup settings such as date and time to run 5 Click Add 6 Click Browse under Backup Source Folder Name ...
Страница 128: ...127 3 Click Edit 4 Click Browse 5 Select the shared folder that you want to make available to iTunes then click OK ...
Страница 131: ...130 9 Click Open Squeezebox The Squeezebox s settings will open ...
Страница 136: ...135 4 Open the License tab then click Activate Free License To deactivate the license click ...
Страница 138: ...137 3 Click Next 4 Click Find Cameras ...
Страница 144: ...143 2 Select the search criteria on the left side of the search screen then click Search ...
Страница 145: ...144 3 The search results are displayed Click a thumbnail to start the media viewer ...
Страница 191: ...190 4 Click Edit Note The settings of the PHP language interpreter can be changed from Edit php ini 5 Click Browse ...