E8: Standard communication parameters
Code
Name
Setting range
Default
Min.
Attri.
E8.01
Communication error
detection time
0.0...60.0 s
(0.0: Inactive)
0.0
0.1
Stop
E8.02
Communication error
protection mode
0: Freewheeling stop
1: Keep running
2: Emergency stop
1
–
Stop
E8.03 Communication process
data loss behavior
0: Decelerating stop
1: Freewheeling stop
2: Keep running
0
–
Stop
E8.10 Modbus baud rate
0: 1,200 bps; 1: 2,400 bps
2: 4,800 bps; 3: 9,600 bps
4: 19,200 bps; 5: 38,400 bps
3
–
Stop
E8.11 Modbus data format
0...3
0
–
Stop
E8.12 Modbus local address
1...247
1
1
Stop
E8.13 Modbus level / edge sen-
sitivity selection
0: Level sensitive
1: Edge sensitive
1
–
Stop
Setting range of E8.11:
0: N, 8, 1 (1 start bit, 8 data bits, 1 stop bit, no parity)
1: E, 8, 1 (1 start bit, 8 data bits, 1 stop bit, even parity)
2: O, 8, 1 (1 start bit, 8 data bits, 1 stop bit, odd parity)
3: N, 8, 2 (1 start bit, 8 data bits, 2 stop bits, no parity)
Bosch Rexroth AG
Appendix
VFC 3210
246/253
DOK-RCON04-VFC3210****-IT01-EN-P
Содержание Rexroth VFC 3210
Страница 1: ...Frequency Converter VFC 3210 Operating Instructions R912007862 Edition 01 ...
Страница 18: ...Bosch Rexroth AG VFC 3210 XVI DOK RCON04 VFC3210 IT01 EN P ...
Страница 146: ...Fig 12 23 Stop DC braking Bosch Rexroth AG Functions and Parameters VFC 3210 118 253 DOK RCON04 VFC3210 IT01 EN P ...
Страница 239: ...Fig 15 2 0020 N 03 0025 N 03 VFC 3210 Bosch Rexroth AG Accessories DOK RCON04 VFC3210 IT01 EN P 211 253 ...
Страница 240: ...Fig 15 3 0008 A 05 Fig 15 4 0020 N 05 Bosch Rexroth AG Accessories VFC 3210 212 253 DOK RCON04 VFC3210 IT01 EN P ...
Страница 249: ...Fig 16 3 Assembly of the fan VFC 3210 Bosch Rexroth AG Maintenance DOK RCON04 VFC3210 IT01 EN P 221 253 ...
Страница 280: ...Bosch Rexroth AG VFC 3210 252 253 DOK RCON04 VFC3210 IT01 EN P ...
Страница 281: ...Notes VFC 3210 Bosch Rexroth AG ...