Code
Name
Setting range
Default
Min.
Attri.
C1.23 Leakage inductance
0.00...200.00 mH
DOM
0.01
Stop
C1.24 Mutual inductance
0.0...3,000.0 mH
DOM
0.1
Stop
For the applications with higher performance requirement in V/f control, motor
parameter auto-tuning is necessary.
The actual no-load current is limited to be less than 75 % of the motor rated cur-
rent.
Example
[C1.07] = 2.06, then set [C1.20] = 2.06, the actual setting value is 1.54.
[C1.07] = 655.00, then set [C1.20] = 655.00, the actual setting value is 491.22.
The application level and setting order of motor parameters
As shown in the table below, the motor control parameters are divided into 4 ap-
plication levels that are interrelated on certain computational basis. In the proc-
ess of parameter setting, the level attribute is a defining factor for the setting of
the parameter value.
Code
Name
Level
C1.01
Motor parameter tuning
Top level
C1.05
Motor rated power
Nameplate level
C1.06
Motor rated voltage
C1.07
Motor rated current
C1.08
Motor rated frequency
C1.09
Motor rated speed
C1.10
Motor rated power factor
C1.12
Motor rated slip frequency
Physical parameter level
C1.20
Motor no-load current
C1.21
Stator resistance
C1.22
Rotor resistance
C1.23
Leakage inductance
C1.24
Mutual inductance
C2.43
Current limitation proportional gain
Control parameter level
C2.44
Current limitation integral time
Tab. 12-14: The application level of motor parameters
The user shall follow the order as specified below to set or modify the parame-
ters, Top level -> Nameplate level -> Physical parameter level -> Control parame-
ter level.
If the user does not conform to the order as specified above, this would cause
undesired change to the parameter setting.
Bosch Rexroth AG
Functions and Parameters
VFC 3210
164/253
DOK-RCON04-VFC3210****-IT01-EN-P
Содержание Rexroth VFC 3210
Страница 1: ...Frequency Converter VFC 3210 Operating Instructions R912007862 Edition 01 ...
Страница 18: ...Bosch Rexroth AG VFC 3210 XVI DOK RCON04 VFC3210 IT01 EN P ...
Страница 146: ...Fig 12 23 Stop DC braking Bosch Rexroth AG Functions and Parameters VFC 3210 118 253 DOK RCON04 VFC3210 IT01 EN P ...
Страница 239: ...Fig 15 2 0020 N 03 0025 N 03 VFC 3210 Bosch Rexroth AG Accessories DOK RCON04 VFC3210 IT01 EN P 211 253 ...
Страница 240: ...Fig 15 3 0008 A 05 Fig 15 4 0020 N 05 Bosch Rexroth AG Accessories VFC 3210 212 253 DOK RCON04 VFC3210 IT01 EN P ...
Страница 249: ...Fig 16 3 Assembly of the fan VFC 3210 Bosch Rexroth AG Maintenance DOK RCON04 VFC3210 IT01 EN P 221 253 ...
Страница 280: ...Bosch Rexroth AG VFC 3210 252 253 DOK RCON04 VFC3210 IT01 EN P ...