Maintenance
5-20
Maintenance
Manual No. 107334
Operating Instructions and Parts List for the Quantum Flex
®
Trimmer
June 22, 2018
DAILY INSPECTION AND MAINTENANCE - WHIZARD
®
FLEXSHAFT AND CASING ASSEMBLY (CONTINUED)
Reassemble the Drive End Assembly to a New Casing
•
If using the casing disconnect, place the disconnect lever (#6) onto the lever mounting collar
(#5).
•
Slip the casing latch collar (#2) or lever mounting collar (#5) with disconnect lever (#6)
onto the new casing.
•
Thread the nylon washer (#3) onto the new casing.
•
Clean the threads of the new casing assembly and apply Loctite #242 Threadlocker or
equivalent.
•
Screw the drive end assembly (#4) on the new casing.
•
Tighten by hand and then with a wrench while holding the casing by hand.
Drive End Assembly Inspection and Replacement
Removal of the driver assembly
•
With one hand, pull the spring (#1) back to
expose the knurled cap (#2) at the end of the
tube.
•
Using the other hand, grip the knurled cap
(#2) with a pair of pliers.
•
Using a 7/16" open end wrench, hold the
flats on the drive end assembly (#3) and turn
the knurled cap (#2) counterclockwise.
•
Unscrew the knurled cap (#2) until the
threads are free from the tube.
•
Pull the driver assembly (#4) out of the
tube.
•
NOTE: NEVER use pliers on the tube as
damage to the internal parts may occur.
NOTICE
DO NOT hold the new casing in a vise or use pliers as damage will occur.
It is not necessary to over-tighten this joint.