Maintenance
5-18
Maintenance
Manual No. 107334
Operating Instructions and Parts List for the Quantum Flex
®
Trimmer
June 22, 2018
DAILY INSPECTION AND MAINTENANCE - WHIZARD
®
FLEXSHAFT AND CASING ASSEMBLY
•
Inspect the casing for any cracks, tears, or other wear. If any damage is found, replace the
casing.
•
Remove the flexshaft from the casing and check for any flexshaft damage, such as broken
wires or kinking. If any damage is detected, replace the flexshaft.
•
Reinsert the flexshaft into the casing, making certain the flange of the flexshaft is pressed
against the bearing inside the casing.
•
Check the extension of the flexible shaft driver at the motor end. The flexible shaft driver
should extend past the motor end fitting. If the shaft extends less than 5/64", replace the
casing.
Bearing
Flex Shaft
Driver
Casing
Motor End
Fitting