Maintenance
Manual No. 107334
Maintenance
5-13
June 22, 2018
Operating Instructions and Parts List for the Quantum Flex
®
Trimmer
DAILY INSPECTIONS & MAINTENANCE (CONTINUED)
Cover Plate
•
Look for signs of corrosion or wear on the cover.
•
Pay special attention to the area covering the gear teeth.
•
If the edge of the cover is worn, exposing the pinion and blade teeth, the cover should be
replaced.
Whizard
®
Micro-Break Hand Straps
•
Inspect the strap for hardening and cracks.
•
If any fibers, cuts, or cracks are showing, the strap should be replaced.
Handle Retaining Knob
•
Inspect for cracks.
•
Make sure spring tension in the metal button is adequate.
•
Make sure the metal button is clean and moves freely.
Frame
•
Inspect the frame surfaces where the housing mounts.
•
Look for corrosion and any nicks or burrs that may prevent proper housing seating.
•
Inspect the housing locating key for damage (Large Tools Only).
•
Inspect frame o-rings for cuts or other damage. Replace if necessary.
Steeling Device - Models: X625, X505, X850, X880, X1850, X1880,
X1000, X1300, X1400 and X1500
•
Inspect the surface condition of the carbide steel. If chipped or cracked it should be replaced.
•
Make sure the steeling device and the plunger are free to move.
•
The plunger and steel should be cleaned and oiled with mineral oil in order to keep free
movement and prevent build-up of dirt.
Depth Gauge / Disc Gauge Clamps - Models: X625, X505, X850,
X880, X1850, X1880, X1000, X1300, X1400 and X1500
•
Inspect the depth gauge / disc for wear or damage.
•
Make certain the depth gauge /disc clamps are not bent.