Set the reel rotation/stop changeover levers
of the gear motors of all mower units (#2,
#3, #4, and #5) except mower unit #1 to the
"Stop" position.
A
B
1
zzpqiy-003
Mower Units #1/#4/#5_006
1
Reel rotation/stop switching lever
A
Rotation
B
Stop
Start the engine, and allow the hydraulic oil
temperature to increase to the same
temperature as during ordinary use.
Check that there is no hydraulic oil leaking
from the location where the pressure gauge
was installed.
Sit on the driver's seat.
Rev the engine at around 2,000 rpm, set
traveling/working changeover switch to
"Working," and then set the reel rotation
switch to "Rotation."
The reel cutter will not rotate as it is
secured with the wooden board, however
hydraulic pressure will be applied.
Rev the engine up to the maximum rpm.
Measure the pressure.
The reel rotation circuit relief valve pressure
is set to 17.2 MPa (175.4 kgf/cm
2
) (2494.6
psi).
8.
9.
10.
11.
12.
13.
14.
Hydraulic System
LM551
Hydraulic System
Page 4-45
Measurement
Содержание LM551
Страница 1: ...5 Unit Reel Mower Service Manual Serial No LM551 10001 Ver 1 0 ...
Страница 4: ...LM551 Introduction ...
Страница 6: ...LM551 Contents ...
Страница 12: ...LM551 Safety Page 1 6 Safety Signs and Instruction Signs ...
Страница 38: ...LM551 Maintenance Standards and Maintenance Page 3 24 Greasing ...
Страница 86: ...LM551 Hydraulic System Page 4 48 Measurement ...
Страница 144: ...LM551 Electrical System Page 5 58 About The Electrical Components ...
Страница 200: ...LM551 Troubleshooting Page 7 10 Mower Unit Related ...
Страница 201: ...Specifications Page 8 2 Maintenance Schedule Page 8 4 List of Consumables Page 8 9 Reference LM551 Reference Page 8 1 ...
Страница 212: ...LM551 Reference Page 8 12 List of Consumables ...