Inspection of Relay (MR5A602A1K)
Remove the relay.
The normal measured resistance between
relay terminals 1 and 2 is about 75 Ω.
2
1
4
3
6
5
2
5
6
1
4
3
38jyg3-004
Inspection of Relay (MR5A602A1K)_001
Normal operation is when there is
conduction between relay terminals 3 and 6
and no conduction between relay terminals
4 and 5.
2
1
4
3
6
5
2
5
6
1
4
3
38jyg3-005
Inspection of Relay (MR5A602A1K)_002
Normal operation is when there is no
conduction between 3 and 6 and there is
conduction between relay terminals 4 and 5
with the battery connected to relay
terminals 1 and 2.
2
1
4
3
6
5
2
5
6
1
4
3
38jyg3-006
Inspection of Relay (MR5A602A1K)_003
1.
2.
3.
4.
Inspection of Relay (CA1aF-12V-N-5)
Remove the power relay.
The normal measured resistance between
relay terminals 1 and 2 is about 80 Ω.
3
4
2
1
3
4
2
1
38jyg3-014
Inspection of Relay (CA1aF-12V-N-5)_001
1.
2.
LM551
Electrical System
Page 5-42
About The Electrical Components
Содержание LM551
Страница 1: ...5 Unit Reel Mower Service Manual Serial No LM551 10001 Ver 1 0 ...
Страница 4: ...LM551 Introduction ...
Страница 6: ...LM551 Contents ...
Страница 12: ...LM551 Safety Page 1 6 Safety Signs and Instruction Signs ...
Страница 38: ...LM551 Maintenance Standards and Maintenance Page 3 24 Greasing ...
Страница 86: ...LM551 Hydraulic System Page 4 48 Measurement ...
Страница 144: ...LM551 Electrical System Page 5 58 About The Electrical Components ...
Страница 200: ...LM551 Troubleshooting Page 7 10 Mower Unit Related ...
Страница 201: ...Specifications Page 8 2 Maintenance Schedule Page 8 4 List of Consumables Page 8 9 Reference LM551 Reference Page 8 1 ...
Страница 212: ...LM551 Reference Page 8 12 List of Consumables ...