Chapter 4: Managing Units
119
4.
Click
Disconnect
. A confirmation dialog box will appear.
For virtual media sessions on DS1030, 1031, 2030, 4030 and 8030 switches only - If you
attempt to disconnect an active virtual media session, or a KVM session that is locked to a
virtual media session, a confirmation message is displayed, indicating that any virtual media
mappings will be disconnected. Click
OK
to confirm or
Cancel
to cancel the disconnect. See
on page 187 for more information.
5.
Click
OK
to disconnect the DSView software sessions.
-or-
Click
Cancel
to cancel the action.
Managing Connections to Units
The
Connections
link displays either target device connections or managed appliance connections.
•
The Target Device Connections window lists all connections to the target device. You may
also use this window to add or delete a connection to or from the target device.
•
The Appliance Connections window lists all connections from the managed appliance to cas-
cade switches or target devices. You may rename the units which are part of the connection
path through this window.
NOTE:
Connections of EVR1500 environmental monitors and generic appliances may not be viewed.
Connection display format
Connections typically appear in a format similar to the following for connections to target devices,
cascade switches and SPC devices:
<Managed appliance name>(<Port>)
→
<EID Number>
→
<target device>
<Managed appliance name>(<Port>)
→
<EID Number>
→
switch one
<Port>
→
<target device>
<Managed appliance name>(<Port>)
→
<SPC Device> (<Port>)
→
<target device>
<DSI5100 Appliance Name>(<Port>)
→
<target device>
The following examples illustrate typical connections that may appear in your DSView
management software.
Example: Target device connections
In the following example, there are three target devices connected to ports 3, 4 and 8 of a DSR1021
switch named dsr-1021-huntsville. The DSR1021 switch ports are connected to the three target
devices using DSRIQ modules. The DSRIQ with an EID of 520255-044F6F is connected to target
device td-john, while 520255-03F757 is connected to td-mary and 520255-016BE0 is connected
to td-tim.
dsr-1021-huntsville(3)
→
520255-044F6F
→
td-john
Содержание DSView
Страница 4: ......
Страница 12: ...x DSView Installer User Guide ...
Страница 18: ...xvi DSView Installer User Guide ...
Страница 50: ...32 DSView Installer User Guide ...