Studio Monitor Pro 2 Operation Guide
145
disabled HW ports, sources, I/O patching and levels are saved and/or recalled using this
feature.
Sample Rate Selector
Allows the ASIO hardware sample rate to be set directly from SMP2. The selected sam-
ple rate is also passed to connected software applications.
13.6.1 Dim level / Fixed Level
DIM
This sets the amount of attenuation (in dB) applied to any program material when the
DIM switch is enabled. (DIM level is a global setting.)
The DIM level is adjustable from the MC Control Room surface section:
1.
Press the DIM button
2.
Turn the CR knob to adjust the amount of attenuation.
Fixed Level
This slider sets the fixed output level, enabled from the Main tab for the Main Control
Room output. This is a useful setting for systems requiring specific monitoring levels
such as SDDS mixing environments.