Media Application Controller Operation Guide
Soft Keys
59
Superlock
Superlock locks the entire MC and CM408T modules (for S5-MC owners) to one appli-
cation, except for the Monitor and Control Room sections, which always lock indepen-
dently of all other sections. This is useful when switching to another application, without
having the MC / System 5-MC constantly switching application sets. For example, you
may switch to a database application to look up samples, but want to lock the MC to your
DAW application.
To engage Superlock, focus to the application you wish to lock to, hold down
Ctrl +
Shift
on the MC keyboard, and press any section’s
Setup
button (except the Monitor and
Control Room
Setup
buttons). The entire MC and CM408T modules, except Monitor
and Control Room, are now locked to that application.
To disengage Superlock, press
Ctrl+Shift+
a
Setup
button again, or press a
Setup
but-
ton (showing the locking tab) and touch the
Unlock All Sections
button on the Touch-
screen.
Содержание MC Pro
Страница 1: ...MC Pro Operation Guide Version 2 5 6 ...
Страница 27: ...Media Application Controller Operation Guide Installation and Configuration 18 ...
Страница 33: ...Media Application Controller Operation Guide Main Touchscreen 24 ...
Страница 84: ...Media Application Controller Operation Guide Studio Monitor Express Windows 87 ...