Standard
RLL
Instructions
5–20
Standard RLL Instructions
Comparative Boolean Instructions
Comparative Boolean
V aaa
The Store If Equal instruction begins a
new rung or additional branch in a rung
with a normally open comparative
contact. The contact will be on when
Vaaa =Bbbb .
B bbb
V aaa
The Store If Not Equal instruction begins
a new rung or additional branch in a rung
with a normally closed comparative
contact. The contact will be on when
Vaaa
Bbbb.
B bbb
Operand Data Type
DL05 Range
B
aaa
bbb
V memory
V
All (See page 4–28)
All (See page 4–28)
Pointer
P
All (See page 4–28)
All (See page 4–28)
Constant
K
––
0–9999
In the following example, when the value in V memory location V2000 = 4933 , Y3 will
energize.
V2000
K4933
Y3
OUT
Direct
SOFT
Handheld Programmer Keystrokes
STR
$
SHFT
4
E
2
C
0
A
0
A
0
A
4
E
9
J
3
D
3
D
ENT
OUT
GX
ENT
3
D
In the following example, when the value in V memory location V2000
5060, Y3
will energize.
Y3
OUT
V2000
K5060
Direct
SOFT
Handheld Programmer Keystrokes
SHFT
OUT
GX
ENT
3
D
4
E
2
C
0
A
0
A
0
A
STRN
SP
5
F
0
A
ENT
6
G
0
A
Store If Equal
(STRE)
Store If Not Equal
(STRNE)
Содержание DL05
Страница 1: ...DL05 User Manual Automationdirect com ...
Страница 2: ...DL05 User Manual Automationdirect com ...
Страница 436: ...1B DL05 Error Codes In This Appendix Ċ Error Code Table ...
Страница 443: ...1C Instruction Execution Times In This Appendix Ċ Introduction Ċ Instruction Execution Times ...
Страница 459: ...1D Special Relays In This Appendix Ċ DL05 PLC Special Relays ...
Страница 464: ...1E DL05 Product Weights In This Appendix Ċ Product Weight Table ...
Страница 466: ...1F European Union Directives CE In This Appendix Ċ European Union EU Directives Ċ Basic EMC Installation Guidelines ...