Getting Started
1–13
Getting Started
Q. Which devices can I connect to the communication ports of the DL05?
A. Port 1:
The port is RS-232C, fixed at 9600 baud, and uses the proprietary
K-sequence protocol. The DL05 can also connect to MODBUS and DirectNET
networks as a slave device through port 1. The port communicates with the following
devices:
S
DV-1000 Data Access Unit or Optimation Operator interface panels
S
Direct
SOFT (running on a personal computer)
S
D2-HPP handheld programmer
S
Other devices which communicate via K-sequence protocol should work
with the DL05 Micro PLC. Contact the vendor for details.
A. Port 2:
The port is RS-232C, with selective baud rates (300-38,400bps), address
and parity.It also supports the proprietary K-sequence protocol as well as DirectNet
and Modbus and non-sequence/print protocols.
Q. Can the DL05 accept 5VDC inputs?
A.
No, 5 volts is lower than the DC input ON threshold. However, many TTL logic
circuits can drive the inputs if they are wired as open collector (sinking) inputs. See
Chapter 2 for I/O wiring guidelines.
Содержание DL05
Страница 1: ...DL05 User Manual Automationdirect com ...
Страница 2: ...DL05 User Manual Automationdirect com ...
Страница 436: ...1B DL05 Error Codes In This Appendix Ċ Error Code Table ...
Страница 443: ...1C Instruction Execution Times In This Appendix Ċ Introduction Ċ Instruction Execution Times ...
Страница 459: ...1D Special Relays In This Appendix Ċ DL05 PLC Special Relays ...
Страница 464: ...1E DL05 Product Weights In This Appendix Ċ Product Weight Table ...
Страница 466: ...1F European Union Directives CE In This Appendix Ċ European Union EU Directives Ċ Basic EMC Installation Guidelines ...