d. SuperTrak motor power supply is powered from an ATS SuperTrak conveyance platform control panel Assy / 25202161 or from other
appropriate power source with certified (North American listed) overcurrent protection, 10A UL489 breaker, type CC fuses or Type J
fuses.
e. The equipment is not evaluated for use in hazardous (classified) environments.
f. The equipment is not evaluated for use with flammable liquids or materials.
g. The equipment has been investigated for continuous operation at a maximum operating ambient temperature of 40°C at an altitude
up to 2000 m and relative humidity levels from 5-90%, non-condensing. All permitted mounting orientations. See
h. The equipment has been evaluated for indoor use in pollution degree 2 environments.
i. The equipment is to be installed by qualified personal in accordance with local and national installation/wiring requirements.
j. Emergency Stop, disconnect devices for the SuperTrak system are provided via the mains supply to the SuperTrak motor power
supply. Integration and validation of system-wide emergency stops are the responsibility of the end user/integrator.
k. Functional Safety requirements are the responsibility of the end user/integrator of this component.
SuperTrak GEN3 Conveyor Control Panel
a. SuperTrak GEN3 conveyor control panel is evaluated as, and is intended only to be used as, an integrated component of the
SuperTrak GEN3 conveyor.
b. SuperTrak GEN3 conveyor control panel is evaluated with scalable supply branches to supply 1 – 12 SuperTrak motor power
supplies Assy / 25270337.
c. The equipment is not evaluated for use in hazardous (classified) environments.
d. The equipment is not evaluated for use with flammable liquids or materials.
e. The equipment has been investigated for continuous operation at a maximum operating ambient temperature of 40°C at an altitude of
up to 2000 m and relative humidity levels from 5-90%, non-condensing.
f. The equipment has been evaluated for indoor use in pollution degree 2 environments.
g. The equipment is to be installed by qualified personal in accordance with local and national installation/wiring requirements.
Adequate ground/bond connection is to be provided to the remote connected SuperTrak motor power supplies (<100mohms tested at
10Amps or greater).
h. Emergency stop, disconnect devices for the SuperTrak system are provided within this control panel. Integration and validation of
system-wide emergency stops are the responsibility of the end user/integrator.
i. Functional safety requirements are the responsibility of the end user/integrator of this component and the integrated system that
consists of the ATS SuperTrak conveyance platform system.
Model Variations:
Certified models SuperTrak GEN3 track module Assy / 1060387 or 1060391 are also represented as 8FZAM1.0A.A000-1 / SuperTrak
straight segment. Models are further supplemented by EN standards as models 25220499.
Certified model SuperTrak GEN3 180 deg section Assy / 1060638 is also represented as 8FZAM2.0A.A000-1 / SuperTrak curve segment.
Certified model SuperTrak motor power supply Assy / 25270337 is also represented as 8FZAP0.00.0100-1 / SuperTrak motor power
supply. Modes are further supplemented by EN standards as models 25195828, 25270354.
Содержание SuperTrak GEN3
Страница 1: ...Rev 9 December 2021...
Страница 2: ......
Страница 3: ...SuperTrak GEN3 Conveyance Platform Modular Conveyor Operation and Maintenance Manual...
Страница 6: ......
Страница 12: ...This page is intentionally blank...
Страница 30: ...This page is intentionally blank...
Страница 58: ...This page is intentionally blank...
Страница 296: ...This page is intentionally blank...
Страница 300: ...This page is intentionally blank...
Страница 364: ...This page is intentionally blank...
Страница 366: ...This page is intentionally blank...