238
SuperTrak™ GEN3 System Operation and Maintenance Manual
Rev. 9 (12-2021)
Technician Procedures
Replace a Flat Wear Strip
Replace a flat wear strip if it becomes damaged.
There are several flat wear strip lengths, depending on the type of sections:
Note that flat wear strip lengths are measured from the
furthest ends of each angle as pictured.
As illustrated in the example below showing a system configuration with straight
and 180 deg. (500 mm) sections, the flat wear strip bridges the join between each
SuperTrak conveyance platform section:
• The flat wear strip must be installed before pallets move on the
SuperTrak conveyance platform. If a flat wear strip is not installed,
pallets will jam against the motors.
• The distance between flat wear strips must be 0.5 mm (0.02 in.).
Description
Length
Part Number
Straight to straight
1.01 m (3.31 ft)
SP-1060669
Straight to 180 deg. (500 mm)
.52 m (1.70 ft)
SP-1060640
Straight to 180 deg. (800 mm) and
Straight to 90 deg.
.54 m (1.77 ft)
SP-25284328
90 deg. to 90 deg.
.075 m (0.25 ft)
SP-125595093
Содержание SuperTrak GEN3
Страница 1: ...Rev 9 December 2021...
Страница 2: ......
Страница 3: ...SuperTrak GEN3 Conveyance Platform Modular Conveyor Operation and Maintenance Manual...
Страница 6: ......
Страница 12: ...This page is intentionally blank...
Страница 30: ...This page is intentionally blank...
Страница 58: ...This page is intentionally blank...
Страница 296: ...This page is intentionally blank...
Страница 300: ...This page is intentionally blank...
Страница 364: ...This page is intentionally blank...
Страница 366: ...This page is intentionally blank...