Technician Procedures
SuperTrak™ GEN3 System Operation and Maintenance Manual
177
Rev. 9 (12-2021)
3. With the metal conduit flush with the
strain relief connectors, tighten the two
(2) strain relief connectors.
4. Feed the required wiring through the metal conduit and connect as required,
then close the sections’ electrical doors.
Straight Section - Left Coil Driver Board
on page 31 for connection information.
Replace a Section-to-Section Electrical Interconnect--Flexible
Connection
Remove the existing flexible conduit
1. Turn the
SuperTrak conveyance platform power disconnect switch
to
the OFF position.
2. Lock out and tag hazardous energy.
3. Access the interior of the sections by:
•
For 180 deg. (500 mm) sections, remove screws and washers from the top
cover of the section, and then lift and remove the top cover.
•
For all other types of sections, use a flat head screwdriver to unlock the
locks, and then open the electrical door.
4. Disconnect and remove all wires that run through the flexible conduit.
5. Loosen the strain relief connectors on the bottom of both adjacent sections.
6. Remove the flexible conduit.
Install the replacement flexible conduit
1. If required, remove the existing electrical interconnect as described above.
2. Carefully bend the flexible conduit, so that one end is in each of the adjacent
section’s strain relief connectors.
Содержание SuperTrak GEN3
Страница 1: ...Rev 9 December 2021...
Страница 2: ......
Страница 3: ...SuperTrak GEN3 Conveyance Platform Modular Conveyor Operation and Maintenance Manual...
Страница 6: ......
Страница 12: ...This page is intentionally blank...
Страница 30: ...This page is intentionally blank...
Страница 58: ...This page is intentionally blank...
Страница 296: ...This page is intentionally blank...
Страница 300: ...This page is intentionally blank...
Страница 364: ...This page is intentionally blank...
Страница 366: ...This page is intentionally blank...