Troubleshooting
SuperTrak™ GEN3 System Operation and Maintenance Manual
267
Rev. 9 (12-2021)
Diagnostic Lights
This section provides information about the indicator lights on the SuperTrak
conveyance platform hardware.
Controller Indicator Lights
The controller has four (4) indicator lights: Power, HDD, Link, and Run.
The following table summarizes the indicator light behavior.
See the
APC910 User’s Manual
for additional information.
Indicator Color Light State Normal
A Problem May Exist
Power
Green Solid
Blinking
A controller hardware problem exists.
Contact your vendor for assistance.
Red
Solid
The controller power is OFF. Press the
power button to turn it ON.
Blinking
A controller hardware problem exists.
Contact your vendor for assistance.
Red/
Green
Blinking
HDD
Yellow Occasional
Blink
Link
Yellow Solid
Normal when an
SDL display is
connected.
Blinking
SDL display power was interrupted.
Check the cables.
Off
Normal when an
SDL display is not
connected.
Содержание SuperTrak GEN3