ADTECH 4 series CNC System (maintainance Manual)
83
019
X Pulse Dir Mode<
●
>
Y Pulse Dir Mode<
●
>
Z Pulse Dir Mode<
●
>
4 Pulse Dir Mode<
●
>
B Pulse Dir Mode<
●
>
C Pulse Dir Mode<
●
>
Range
:
0
~
1
Unit
:
Authority
:
Operation admin or higher
Default
:
0
Effective time
:
reboot
Note
: Pulse command format setting is to configure the mode of output pulse.
The compatible command format of the motor drive should be known in
advance.
0
is Pulse + pulse mode
1
is Pulse + direction model
Range
:
0
~
1
Unit
:
Authority
:
Operation admin or higher
Default
:
0
Effective time
:
reboot
Note
:
Set pulse direction; if the controller direction is reverse to actual
direction, please modify this parameter to adjust the direction of motor.
Range
:
0
~
1
Unit
:
Authority
:
Operation admin or higher
Default
:
0
Effective time
:
Instant
X Ext Home ELevel
Y Ext Home ELevel
Z Ext Home ELevel
4 Ext Home ELevel
B Ext Home ELevel
C Ext Home ELevel
020
B Pulse Mode<
●
>
C Pulse Mode<
●
>
Содержание 4 Series
Страница 1: ...1 ADTECH 4 SERIES CNC MAINTAINANCE USER MANUAL ...
Страница 65: ...ADTECH 4 series CNC System maintainance Manual 61 Instant ...
Страница 110: ...ADTECH 4 series CNC System maintainance Manual 106 12 1 2 49serise Mounting dimensions ...
Страница 124: ...ADTECH 4 series CNC System maintainance Manual 120 12 3 Electrical connection diagram 12 3 1 Electrical Symbol ...
Страница 125: ...ADTECH 4 series CNC System maintainance Manual 121 12 3 2 Main Power connection diagram ...
Страница 126: ...ADTECH 4 series CNC System maintainance Manual 122 12 3 3 Servo drive connection diagram ...
Страница 127: ...ADTECH 4 series CNC System maintainance Manual 123 12 3 4 Step connection diagram ...