ADTECH 4 series CNC System (maintainance Manual)
22
5.7
BDT function
at auto mode, press [BDT] to start the BDT function, which will make the instructions invalid, the
instructions are that hace a ‗/‘ symbol at the begaining of program segments.
5.8
Stopping automatic operating
Two methods are available to stop automatic operating,one is that when the controller exctue M01 or
M00 code,the other is that press stop key on the panel
Program stops
After executing M00 or M01 code, the controller stop automaticly, which is same as SBK
function,after press [start],the controller continue working
After finish a work piece ,the controller stop automaticly
Program ends
After executing M30, the controller stop automaticly, and returns to program start.point
Feeding pause
During automatic operation, press the [Pause] key on the operation panel, the automatic operation
pauses and the indicator is on; press [Start] again to continue working and the pause indicator is off
Reset
During automatic operation, press the [Reset] key on the operation panel and the system stops
immediately. Here, [Reset] is same as emergency stop button.
Содержание 4 Series
Страница 1: ...1 ADTECH 4 SERIES CNC MAINTAINANCE USER MANUAL ...
Страница 65: ...ADTECH 4 series CNC System maintainance Manual 61 Instant ...
Страница 110: ...ADTECH 4 series CNC System maintainance Manual 106 12 1 2 49serise Mounting dimensions ...
Страница 124: ...ADTECH 4 series CNC System maintainance Manual 120 12 3 Electrical connection diagram 12 3 1 Electrical Symbol ...
Страница 125: ...ADTECH 4 series CNC System maintainance Manual 121 12 3 2 Main Power connection diagram ...
Страница 126: ...ADTECH 4 series CNC System maintainance Manual 122 12 3 3 Servo drive connection diagram ...
Страница 127: ...ADTECH 4 series CNC System maintainance Manual 123 12 3 4 Step connection diagram ...