ADTECH 4 series CNC System (maintainance Manual)
66
012
System Baudrate
013
Controler ID
015
016
G73(M)LoopObligate(mm)
G83(M)LoopObligate(mm)
Note
:
While editing G code manually, after this line is finished ,the program
add a line number Nxxxxx automatically in a new line;
0 indicates that this function is disabled;
Range
:
9600~115200
Unit
:
None
Authority
:
Operation admin or higher
Default
:
115200
Effective time
:
Reboot
Note
:
The communication rate setting for connection PC software when the
controller communicate with pc software via RS232
Range
:
1~250
Unit
:
None
Authority
:
Operation admin or higher
Default
:
1
Effective time
:
Reboot
Note
:
The communication rate setting for connection PC software when the
controller communicate with pc software via RS232 or network(RJ45)
Range
:
0~1
Unit
:
mm
Authority
:
Operation admin or higher
Default
:
0.2
Effective time
:
Instant
Note
:
Set the arc interpolation equivalent
If this value is too small, the arc is more better , but the
internal
algorithm is more complicated(as you know ,the Arc G code which
inported from CAM software are composed by lots of small lines) , so
that the controller response speed is slow ,it will take more time to
excute program .the default value is ok .
Range
:
0.1~100
Unit
:
mm
Authority
:
Operation admin or higher
Default
:
2.000
Effective time
:
Instant
014
Circle InpUnit(mm)
Содержание 4 Series
Страница 1: ...1 ADTECH 4 SERIES CNC MAINTAINANCE USER MANUAL ...
Страница 65: ...ADTECH 4 series CNC System maintainance Manual 61 Instant ...
Страница 110: ...ADTECH 4 series CNC System maintainance Manual 106 12 1 2 49serise Mounting dimensions ...
Страница 124: ...ADTECH 4 series CNC System maintainance Manual 120 12 3 Electrical connection diagram 12 3 1 Electrical Symbol ...
Страница 125: ...ADTECH 4 series CNC System maintainance Manual 121 12 3 2 Main Power connection diagram ...
Страница 126: ...ADTECH 4 series CNC System maintainance Manual 122 12 3 3 Servo drive connection diagram ...
Страница 127: ...ADTECH 4 series CNC System maintainance Manual 123 12 3 4 Step connection diagram ...