ADTECH 4 series CNC System (maintainance Manual)
74
057
System boot zero way
060
4 axis max rotate speed
If it is OFF ,it will not jump when excute M98 code
Range
:
Non RZ/ Prompt RZ / Auto RZ
Unit
:
Authority
:
Operation admin or higher
Default
:
Non RZ
Effective time
:
Instant
Note
:
Non RZ: after power on controller ,it will keep the last system
coordinate
Prompt RZ: after power on controller ,it will show message that remind
u return zero or not ,if press EOB,it will return zero,if press cancel ,it will
keep the last system coordinate
Auto RZ: after after power on controller,it will return zero automatic
Range
:
0---3922
Unit
:
ms
Authority
:
Operation admin or higher
Default
:
0
Effective time
:
Instant
Note
:
after the spindle stop working , the controller has a delay and output a
signal to Make the spindle brake signal inactive
Range
:
Unit
:
Authority
:
Operation admin or higher
Default
:
0
Effective time
:
Instant
Note
:
This parameter is invalid now ,so no need set it
Range
:
1--500
Unit
:
Authority
:
Operation admin or higher
Default
:
50
Effective time
:
Instant
Note
:
If the P1.018 setting is angle ,then this setting for setting the max speed
of A axis(when theA axis is rotary ,not linear )
Range
:
0--1
Unit
:
none
Authority
:
Operation admin or higher
Default
:
0
Rotation axis opt feature
059
Spi brake deay(ms)
058
061
Hand wheel encoder dir
Содержание 4 Series
Страница 1: ...1 ADTECH 4 SERIES CNC MAINTAINANCE USER MANUAL ...
Страница 65: ...ADTECH 4 series CNC System maintainance Manual 61 Instant ...
Страница 110: ...ADTECH 4 series CNC System maintainance Manual 106 12 1 2 49serise Mounting dimensions ...
Страница 124: ...ADTECH 4 series CNC System maintainance Manual 120 12 3 Electrical connection diagram 12 3 1 Electrical Symbol ...
Страница 125: ...ADTECH 4 series CNC System maintainance Manual 121 12 3 2 Main Power connection diagram ...
Страница 126: ...ADTECH 4 series CNC System maintainance Manual 122 12 3 3 Servo drive connection diagram ...
Страница 127: ...ADTECH 4 series CNC System maintainance Manual 123 12 3 4 Step connection diagram ...