AB phase input allows differential connection and common anode connection, which will be
determined by the encoder type
As shown in the figure below, differential input connection and common anode connection
Differential connection follows:
5V power supply should be external
Common anode connection follows:
The power supply is determined by encoder. If 5V power supply is used, resistor R will be unnecessary.
For 12V power supply, please use 1K-2K resistor, and for 24V power supply, please use 2K-5K resistor.
Suggestion:
Please use differential connection to ensure better anti-interference when the conection wires arelong.
20
21
22
23
24
25
26
DAOUT2
DAOUT1
DAGND
AXIS 1
AXIS 3
AXIS 5
24V-
2
nd
analog output (0—10V)
1
st
analog output (0—10V)
Analog output GND
Spinde out1(CW)
Spinde out3
Spinde out5
24V-