6.2.4 A1A2_BS
Table 7: Input signals for A1A2_BS
IN:
DESCRIPTION:
IHxx-Q0_OP
Signal is 1 if Q0 is open
IHxx-Q0_CL
Signal is 1 if Q0 is closed
IHxx-Q11_OP
Signal is 1 if Q11 is open
IHxx-Q11_CL
Signal is 1 if Q11 is closed
IHxx-Q12_OP
Signal is 1 if Q12 is open
IHxx-Q12_CL
Signal is 1 if Q12 is closed
IHxx-Q51_OP
Signal is 1 if Q51 is open
IHxx-Q51_CL
Signal is 1 if Q51 is closed
IHxx-Q52_OP
Signal is 1 if Q52 is open
IHxx-Q52_CL
Signal is 1 if Q52 is closed
IHxx-A1Q15_OP
Signal is 1 if Q15 on busbar A1 is open
IHxx-A1Q15_CL
Signal is 1 if Q15 on busbar A1 is closed
IHxx-A2Q15_OP
Signal is 1 if Q15 on busbar A2 is open
IHxx-A2Q15_CL
Signal is 1 if Q15 on busbar A2 is closed
IHxx-BBTR_OP
Signal is 1 if no busbar transfer is in
progress concerning this bus section
IHxx-VP_BBTR
Switch status are valid for all apparatuses
involved in the busbar transfer
IHxx-EXDUP_AB
Signal is 1 if there is no transmission error
from any bay connected to the AB busbars
IHxx-EXVVA_AB
Signal is 1 if the interlocking programs in all
bays connected to the AB busbars are run-
ning
IHxx-EXDUP_ES
Signal is 1 if there is no transmission error
from any bay containing earthing switches
Q15 in section A1 and A2
IHxx-EXVVA_ES
Signal is 1 if the interlocking programs in all
bays containing earthing switches Q15 in
section A1 and A2 are running
IHxx-Q0_O_EX1
Input for an external open condition for
apparatus Q0
IHxx-Q0_O_EX2
Input for an external open condition for
apparatus Q0
IHxx-Q0_O_EX3
Input for an external open condition for
apparatus Q0
IHxx-Q11EX1
Input for an external condition for apparatus
Q11
IHxx-Q11EX2
Input for an external condition for apparatus
Q11
IHxx-Q12EX1
Input for an external condition for apparatus
Q12
IHxx-Q12EX2
Input for an external condition for apparatus
Q12
Содержание REC 561
Страница 19: ...ABB Network Partner AB Introduction REC 561 Version 1 0 00 1MRK 580 146 XEN Page 2 14 ...
Страница 31: ...ABB Network Partner AB Requirements and basic technical data REC 561 Version 1 0 00 Page 2 26 ...
Страница 49: ...ABB Network Partner AB Page IV ...
Страница 67: ...ABB Network Partner AB Installation and commissioning Version 1 0 00 1MRK 580 166 XEN Page 3 18 ...
Страница 85: ...ABB Network Partner AB Local man machine communication Version 1 0 00 1MRK 580 156 XEN Page 3 36 ...
Страница 121: ...ABB Network Partner AB Menu tree Appendix Version 1 0 00 1MRK 580 158 XEN Page 3 72 ...
Страница 139: ...ABB Network Partner AB Terminal identification Version 1 0 00 1MRK 580 160 XEN Page 4 4 ...
Страница 143: ...ABB Network Partner AB Activation of setting group Version 1 0 00 1MRK 580 162 XEN Page 4 8 ...
Страница 175: ...ABB Network Partner AB Configurable logic Version 1 0 00 1MRK 580 161 XEN Page 4 40 ...
Страница 261: ...ABB Network Partner AB Auto reclosing Single and or three phase Version 1 0 00 1MRK 580 170 XEN Page 5 82 ...
Страница 281: ...ABB Network Partner AB Loss of power system voltage Version 1 0 00 1MRK 580 153 XEN Page 5 102 ...
Страница 385: ...ABB Network Partner AB Apparatus control Version 1 0 00 1MRK 580 150 XEN Page 6 100 ...
Страница 495: ...ABB Network Partner AB Interlocking Version 1 0 00 1MRK 580 151 XEN Page 6 210 ...
Страница 515: ...ABB Network Partner AB Event function Version 1 0 00 1MRK 580 140 XEN Page 6 230 ...
Страница 519: ...ABB Network Partner AB Page IV ...
Страница 561: ...ABB Network Partner AB Time synchronisation Version 1 0 00 1MRK 580 135 XEN Page 7 42 ...
Страница 569: ...ABB Network Partner AB Internal events Version 1 0 00 1MRK 580 134 XEN Page 7 50 ...
Страница 599: ...ABB Network Partner AB Index Version 1 0 01 1MRK 580 175 XEN Page 8 6 ...
Страница 634: ......
Страница 635: ......
Страница 636: ......
Страница 637: ......
Страница 638: ......
Страница 639: ......
Страница 640: ......
Страница 641: ......
Страница 642: ......
Страница 643: ......