Page
73
AD-4410
11.4. RS-232C (Standard) / RS-232C (ch2) / RS-485
Function No.
Parameter or
Setting range
Description
Default
value
User
setting
Sr51f01
r52f01
1
to
5
Output data
1
: Display weighing value
2
: Gross weight
3
: Net weight
4
: Tare weight
5
: Gross weight / Net weight / Tare weight
1
Sr51f02
r52f02
1
to
4
Data transfer mode
1
: Stream (Every time display refreshes)
2
: Auto print
3
: Manual print
4
: Jet stream (Every sampling)
1
Sr51f03
r52f03
1
to
7
Baud rate
1
: 600bps
2
: 1200bps
3
: 2400bps
4
: 4800bps
5
: 9600bps
6
: 19200bps
7
: 38400bps
3
Sr51f04
r52f04
0
to
2
Number of data bits, parity
0
: 8-bit data, no parity
1
: 7-bit data, odd parity
2
: 7-bit data, even parity
2
Sr51f05
r52f05
1
to
2
Terminator
1
: CR, LF
2
: CR
1
Sr51f06
r52f06
0
to
99
ID number
0: None
1 to 99
0
Sr51f07
r52f07
1
to
2
Decimal point / Delimiter
1
: Decimal point: dot / Delimiter: comma
2
: Decimal point: comma / Delimiter:
semicolon
1
Sr51f08
r52f08
0
to
1
Time out
1
: No limit
2
: Approx. 1 second
1
Sr51f09
r52f09
0
to
4
Delay when outputting repeatedly
0
: No delay
1
: Approx. 0.5 second
2
: Approx. 1.0 second
3
:
Approx. 1.5 second
4
:
Approx. 2.0 second
0
Sr52f10
0
to
1
Internal terminator resistance
0
: None
1
: Available (120
Ω
)
Available only when RS-485 is used
0
Содержание AD-4410