AD-4410
Page
52
9.2.3. RS-485 (AD4410-03)
Optionally installed on the AD-4410.
Signal form
: EIA RS-485 compliant
Baud rate
: 600, 1200, 2400, 4800, 9600, 19200, 38400 bps
Data bits
: 7 or 8 bits
Parity
: 1 bit, Even or Odd (Data bits 7 bits)
None (Data bits 8 bits)
Start bit
: 1 bit
Stop bit
: 1 bit
Signal wire
: Twin wires method
Drop number
: Up to 32
Terminator resistor : 120
Ω
(Can select internal connection)
Character code
: ASCII, JIS 8
Connector
: 7 pin DIN connector
Connection
Pin No. Signal name
Direction
Description
1 A I/O
Transmission
data
2 B I/O
Received
data
4 SG -
Signal
ground
6,7
Not used (No connection)
3,5
Current loop output
Shell FG
-
Shield
* Do not connect to the current loop output.
* Depending on the model, the A and B terminals of the RS-485 may be reversed.
* When there is no signal ground for the RS-485, there is no need to wire the SG
terminal
* Connect to the FG terminal when a shield connection is required.
C.L./OP internal circuit
Adaptive connector JA-TCP0576 (provided)
Fig.12 Option internal circuitry (AD4410-03)
Internal circuit of the
AD4410-03
RS-485
Shell
FG
NC
NC
SG
A
B
RE/DE
Содержание AD-4410