8.4. Hold
Function No.
Parameter
range
Function Description
Default
value
LHldf01
0.00
to
9.99
Averaging
time
Time to perform the averaging.
Units in seconds.
0.00 is not averaged.
0.00
LHldf02
0.00
to
9.99
Start wait
time
Time to wait before commencing hold or
averaging.
Units in seconds.
0.00
LHldf03
0
to
2
Condition of
automatic
start
Condition to start the hold or averaging
automatically
0
: Do not use automatic start.
1
Above the near-zero range, and stable
2
Above the near-zero range
0
LHldf04
0
to
1
Release due
to falling
control input
Release when control input is falling
0
: Do not release
1
: Release
1
LHldf05
0.00
to
9.99
Time
release
Release after a set amount of time
has passed
Units in seconds.
Release will not happen if the value is set
to 0.00.
0.00
LHldf06
0
to
999999
Release due
to range of
fluctuation
Release when fluctuation from the
holding value exceeds a set value
The decimal point position is linked to
Calf02
.
Release will not happen if the value is set
to 0.
0
LHldf07
0
to
1
Release in
near-zero
range
Release when the weighing value is in
the near-zero range
0
: Do not release
1
: Release
0
* This hold function only works when
fncf07
(hold) is set to
2
(peak hold) or
3
(averaging
hold). This hold function has no function when
fncf07
(hold) is set to
1
(normal hold).
*
Hldf01
(averaging time) works only when
fncf07
(hold) is set to
3
(averaging hold).