Page
49
AD-4410
9. Interface
9.1. Control I/O
- Display and data output can be controlled externally using control input.
- Weighing states and results can be output to external devices using control output.
- User I/O can check and control sensors and switches other than the AD-4410.
Sensors and switches can be controlled together with the AD-4410, eliminating the
need for additional specialized equipment.
9.1.1. Specification
Input circuit method
DC input (Source type)
Input terminal open voltage
Approx. 5V
Input circuit driving current
5mA (Maximum)
Allowable residual voltage
2V (Maximum)
Output circuit method
Open corrector output
Output circuit pressure-resistance
DC40V
Allowable driving current
50mA
Output terminal residual voltage
1.5V (When driving current is 50mA)
9.1.2. Connection
Function Pin
No.
Signal
name
Description
7
IN1
Control input 1
5
IN2
Control input 2
3
IN3
Control input 3
Control input
2
COM (in)
Common terminal of control input
6
OUT1
Control output 1
4
OUT2
Control output 2
1
OUT3
Control output 3
Control
output
8
COM (out) Common terminal of control output
Shell
FG
Earth
Adaptive connector JA-TCP0586 (provided)
Fig.9 Internal circuit of control I/O
OUT2
1k
Ω
IN1
IN3
IN2
COM(in)
COM(out
)
OUT1
OUT3
1k
Ω
1k
Ω
+5V
Internal circuit