Page
43
AD-4410
8.3. Basic Functions (
fncf
)
Function No.
Parameter
range
Function Description
Default
value
F
fncf01
000000
to
111111
Disable key
switch
Each digit of the setting corresponds to a
key switch. Only available in the weighing
mode.
0
: Does not disable the key switch function.
1
: Disables the key switch function.
Key assignment to each binary digit
6
th
5
th
4
th
3
rd
2
nd
1
st
000000
(binary)
fncf02
0
to
6
F key
Assigns a function to the F key.
0
: None
1
: Manual print command
2
: Hold
3
: Alternate switch
4
: Momentary switch
5
: Clear the tare weight
6
: Clear the zero value
NOTE: Clearing the zero value can be
enabled or disabled by
Calf15
0
fncf03
1
to
3
Display
update rate
1
: 20 times/second
2
: 10 times/second
3
: 5 times/second
1
fncf04
0
to
13
display
Assigns a function to the
display.
0
: None
1
: Zero tracking in progress
2
: Alarm (Zero range setting error, over)
3
: F key status
4
: Near zero
5
: HI output (Over the upper limit value)
6
: OK output (Within upper and lower limit
values)
7
: LO output (Below the lower limit value)
8
: User input 1
9
: User input 2
10
: User input 3
11
: User output 1
12
: User output 2
13
: User output 3
0
fncf05
0
to
16
Digital filter
Selects a cutoff frequency.
0
: None
1
: 11.0 Hz
2
: 8.0 Hz
3
: 5.6 Hz
4
: 4.0 Hz
5
: 2.8 Hz
6
: 2.0 Hz
8
ZERO
TARE
Net/B/G
NET GROSS
ON/OFF
ESC
ENTER
Содержание AD-4410