AD-4410
Page
48
8.7. RS-232C (Standard) / RS-232C (ch2) / RS-485
Function No.
Parameter or
Setting range
Function Description
Default
value
Sr51f01
r52f01
1
to
5
Output data
1
: Displayed weight
2
: Gross weight
3
: Net weight
4
: Tare weight
5
: Gross / Net / Tare
When the data transfer mode is set to
jet stream, 5: will output the load cell
output signal at 0.00001mV/V.
1
Sr51f02
r52f02
1
to
4
Data transfer
mode
1
: Stream (Every time display is
refreshed)
2
: Auto print
3
: Manual print
4
: Jet stream (Every sampling)
1
Sr51f03
r52f03
1
to
7
Baud rate
1
: 600bps
2
: 1200bps
3
: 2400bps
4
: 4800bps
5
: 9600bps
6
: 19200bps
7: 38400bps
3
Sr51f04
r52f04
0
to
2
Parity of
number of
data bits
0
: 8-bit data, no parity
1
: 7-bit data, odd parity
2
: 7-bit data, even parity
2
Sr51f05
r52f05
1
to
2
Terminator
1
: CR, LF
2
: CR
1
Sr51f06
r52f06
0
to
99
ID number
0
: None
1 to 99
0
Sr51f07
r52f07
1
to
2
Decimal
point/
Delimiter
1
: Decimal point: dot / Delimiter: comma
2
: Decimal point: comma / Delimiter:
semicolon
1
Sr51f08
r52f08
0
to
1
Time out
1
: No limit
2
: Approx. 1 second
1
Sr51f09
r52f09
0
to
4
Delay when
outputting
repeatedly
0
: No delay
1
: Approx. 0.5 second
2
: Approx. 1.0 second
3
: Approx. 1.5 second
4
: Approx. 2.0 second
0
Sr52f10
0
to
1
Internal
terminating
resistance
0
: Off
1
: On (120
Ω
)
Available only when using RS-485
0