Start-up
|
-
"
U
360
V
|
-
"
360
Rated voltage
Select parameter
"U"
Enter nominal voltage of the motor
Start-up
|
-
"
f
5.5
rpm
|
-
"
5.5
Rated power
Select parameter
"P"
Enter nominal power of the motor
Start-up
|
-
"
cos phi 0.75
|
-
"
0.75
Power factor
Select parameter
"cos phi"
Enter power factor of the motor
Possible only for asynchronous motors
Start-up
|
-
"
TYPE
Star
|
-
"
Triangle
Connection type
Select parameter
"TYP"
Choose connection type of the motor
Start-up
|
-
"
ENC_TYP EnDat/SSI
|
-
"
EnDat/SSI
Encoder type
Select parameter
"ENC_TYP"
Enter the type of encoder used
Start-up
|
-
"
ENC_INC 2048
INC
|
-
"
2048
Encoder resolution
Select parameter
"ENC_INC"
Enter the encoder resolution
Start-up
|
-
"
BC_TYP
BR11
|
-
"
BR11
BR/BC type
Select parameter
"BC_TYP"
Enter the used brake resistor or brake chopper
Start-up
|
-
"
V*
1.00
m/s
|
-
"
1.00
Nominal speed
Select parameter
"V*"
Enter the installation rated speed
Start-up
|
-
"
__D
0.315
m
|
-
"
0.400
Driving disk diam.
Select parameter
"__D"
Enter the diameter of the traction sheave
Original operating instructions
ZETADYN 3C
Start-up
R-TBA08_03-GB 1619
Part.-No. 00163322-GB